NEWS CENTER

LONGHENG YUYINGLI

02

2022

-

08

Steel strand manufacturer: What is the main function of bridge prestressed steel strand?


Steel wire strand manufacturer: What is the main function of prestressed steel wire strand for bridges?

Steel wire strand is a steel material formed by twisting multiple steel wires together. The surface of carbon steel can be plated with zinc, zinc-aluminum alloy, aluminum, copper, epoxy resin, etc., according to customer needs. In daily life, the application of steel wire strand in China is becoming more and more widespread. In layman's terms, steel wire strand is mainly used in civil engineering projects with large static loads, such as the construction of bridges, large-span factories, or high-rise buildings. So, steel wire strand manufacturer: What is the main function of prestressed steel wire strand for bridges?

 Steel wire strand manufacturer

Steel wire strand manufacturer: What is the main function of prestressed steel wire strand for bridges?

1. Generally, prestressed steel wire strands are bonded prestressed steel wire strands. Because they do not have an insulating plastic sheath on the surface, they are bonded to the concrete when used in pretensioned prestressed members; when used in post-tensioned prestressed members, they are bonded with grouting.

2. Before the structural member bears the external load, prestress should be applied to the reinforcement in the tensile member to improve the stiffness of the member, delay the cracking time, and increase the durability of the member. In terms of mechanical structure, it means to pre-stress it, and its advantage is that it can improve the stiffness of the structure itself, reduce vibration and elastic deformation. This can significantly improve the elastic strength of the tensile module and make the original resistance stronger.

3. Before the structure bears the external load, compressive stress is applied in advance to the tensile zone under the external load to improve the performance of the structure. This structure is called a prestressed structure. For example, a wooden barrel. Before filling it with water, use iron or bamboo hoops to tighten the barrel wall, creating hoop compressive stress on the barrel wall. If the applied compressive stress offsets the tensile stress caused by the water pressure, the barrel will not crack or leak. Applying prestress to a circular water tank is like the hoops in a wooden barrel. Similarly, applying prestress to a flexural member before the load increases will produce a deformation opposite to that caused by the load. Before the load causes the member to deform in another direction, the deformation opposite to the load direction must first be offset before the member can continuously deform in the load direction. In this way, prestressing is equivalent to adding a layer of protection to the member.

Steel wire strand manufacturer: Copper-clad Steel wire strand In Wiring What is its role in the process?

During the wiring process, it is necessary to measure whether the grounding resistance is small enough. It is very dangerous for users of high-rise residential buildings to use water pipes or gas pipes as grounding bodies, because the surfaces of water pipes and gas pipes are coated with anti-corrosion coatings, and the joints of water pipes are sealed with plastic materials. The underground part of the water pipe uses PVC pipes, but these are poor conductors and have no safety guarantee. When inspecting steel wire strands, a multimeter DC voltage block is generally used to test whether the X1 voltage of the workbench socket can be used normally. If it is normal, it means that the front-end working circuit can work, and the fault is mainly in the back-end. Check whether the plug and socket are loose. If the DC voltage is normal and the plug and socket are in good contact, check whether the coil of the electromagnetic workbench is open or short-circuited and burned out. Measure the electromagnetic chuck coil with a multimeter. If there is an open circuit or the resistance value is smaller than usual, it means that the electromagnetic workbench coil is burned out. At this time, the same type of electromagnetic workbench coil should be replaced.